izindaba

Amacala amabi nezisombululo

 

Amakhasimende amaningi angahlangabezana nezimo lapho umshini wokuphambuka we-cryogenic ehluleka ukusebenza kahle ngesikhathi sokusebenza kwawo ngenxa yezici zemvelo noma amaphutha okusebenza. Lapho ufuna ukwesekwa ngemuva kokuthengisa, kungenzeka ukuthi ngeke bakwazi ukubona imbangela, okuholela ekutheni kube nakuqala, uhlelo kanye noshintsho oluhlelekile, nemiphumela engaphenduki. Le ndatshana ihloselwe ukubhekana nokuxazulula inkinga kokuhleleka kweqhwa esimweni esingalimalis.

 

Iziko

Izimbangela ezingaba khona

Izindlela

1. Imidiya ayikhishwa

Inani elanele lama-medias

Qinisekisa inani le-medias

Ama-Medias amanzi noma aqandisiwe

Buyisela ama-medias omisiwe

I-Media Feed Tube Interface ku-Media Bin ivinjelwe yi-Burrs

Sula ukuvalwa kwama-burrs kuma-media mediaisikhombimsebenzisi.

I-Media feed Tube ivinjelwe yimibumbi

Sula ukuvalwa kwama-burrs ngaphakathi kokudlulisela ipayipi.

I-Media yokuthaka ishubhu yesondo ivinjelwe yi-burrs

Susa ama-bolts ahleliwe ngaphakathi kwephayimu yokumunca yesondo, futhi uhlanze ama-burrs. Qaphela: Ungayinaki i-deflector

Isihlukanisi esivelayo sivinjelwe yimibumbi

Susa ama-berrs aqothulayo esikrinini esidlikizayo.

Ukuxhumana okulimele epayipini okudlulisa kubangele ukuvuza kwabezindaba

Buyisela ipayipi elisha

Isondo le-2.projectale alizungezi

Umnyango wegumbi lokusebenza awuvaliwe ngokuphelele

Vala umnyango wekamelo elisebenzayo ngokuphelele.

Ukuthwala injini kushisiwe

Khomba imbangela yomthwalo wokushiswa oshisiwe bese ubeka esikhundleni semoto ehambisana nentsha.

3. IBarrel ayizungezi

Isixhumi phakathi kwe-Barrel ejikelezayo Shaft futhi imoto yonakele

Khomba imbangela yomonakalo bese ubuyisela isixhumi esisha se-Umbrella Giar.

Idivaysi ye-Barrel Drive nayo iyalinyazwa

Khomba imbangela yomonakalo bese ubeka esikhundleni sedivaysi entsha yokushayela nezinye izinto.

4.Temperature ngaphakathi kwe-Work Chamber ayikwazi ukwehla

Akukho ukuhanjiswa kwe-nitrogen ewuketshezi

Bheka ukuthi i-valve eyinhloko yethangi ivuliwe, uma ama-valves epayipi evulekile, futhi uma i-vent valve ivaliwe. Bheka ukuthi ngabe kukhona i-nitrogen ezanele ethangini, futhi uma ukucindezela kokuhlinzekwa kuphakathi kuka-0.5 ~ 0.7MPA.

I-liquid nitrogen nozzle ivinjiwe

Susa izinto ze-nozzle nezitolo ezicacile

I-electromagnetic valve yesijobelelo se-nitrogen i-litrogen ayisebenzi kahle

Buyisela i-valve ye-electromagnetic.

Ukudlidliza okungu-5.Abnormil ekujikelezeni kwesondo

Ukulimala kwezimoto ezithwala izimoto nezinye izingxenye

Buyisela izingxenye ezilimele zemoto


Isikhathi Seposi: Meyi-30-2024